SIMPLE OPERATION
Easy set up of the drive can be done using the main control panel or via a standard communications interface from a host computer.
Fast configuration of standard applications can be achieved using 10 parameters or less.
FASTER DRIVE SETUP
Programming the Mentor II has never been easier.
Designed to save commissioning time, the drive has easily assimilated function menus browsed and edited via five navigator keys.
BETTER CONTROL
A comprehensive self-tuning algorithm gives improved current loop performance for a more uniform response at all speeds. Drive performance is also enhanced with full PID digital speed control.
MORE FUNCTIONS
The main circuit board has been developed to incorporate many additional features as standard.
MASSIVE SYSTEMS POTENTIAL
All analogue inputs and most of the digital control inputs are user-configurable, making Mentor II a true systems drive having more versatility and flexibility than ever before.
WIDE RANGING, MORE FLEXIBLE COMMUNICATIONS
Mentor II is able to communicate directly with PLCs and host computers or via optional interface cards.
This is achieved with the standard RS485 port.
DIGITAL SPPED AND POSITIONING LOOP
This allows several drives to be run in speed or position synchronization.
CENTREWINDER
The drive torque is continuously adjusted to compensate for changing coil diameter, machine losses and coil inertia.
SHAFT ORIENTATION
This allows the user to specify the final position of the motor shaft relative to an electronic feedback datum, for example a marker pulse from an encoder.
The position is adjusted by simply changing the value of the appropriate parameter.
"S" RAMP
This facility provides a curved function at each of a user defined acceleration/deceleration ramp.
MENTOR II SPECIFICATIONS
ENVIORNMENT
Ambient Operating Temperature 0 to 40°C Derate current 1.5% per °C to 55°C
Cooling Method Convection and forced convection, model dependent
Humidity 95% non-condensing at 40°C
Storage Temperature -40 to 55°C
Altitude 0 to 4000m Derate 1% per 100m between 1000m and 4000m
Enclosure Chassis (IP00)
AC Supply Requirements
Voltage 208 to 480 VAC -5% +10%
525/575/660 VAC ±10% (Optional M350 and above)
Phase 3Ø
Frequency 45 to 62 Hz
Efficiency 98%
CONTROL
Feedback Methods Armature Voltage (resolution 0.83 volts)
DC Tachometer (resolution 0.1%)
Encoder (resolution .01%)
Field Control Current regulated 8 Amps max (M210/M210R and smaller)
Voltage regulated .675 or .9 X Line-to-line voltage (M350/M350R and larger)
Analog Input Resolution 12 bit (Qty 1), 10 bit (Qty 4)
Serial Communications 4-wire RS422 or RS485
optically-isolated Protocol is ANSI x 3.28-2.5-A4
Baud rate is 4800 or 9600
PROTECTION
AC Line Undervoltage Trip 180 VAC
MOV Voltage Transient Protection Input transient suppression
Instantaneous Overcurrent Trip 300% armature current
Armature Open Circuit Armature circuit is open
Drive Overload Trip Inverse time, 150% for 30 seconds
Phase Loss Trip Loss of input phase
Overtemperature Trip Heatsink exceeds 100°C
Motor Thermal Trip Motor over-temp switch or Thermistor
Feedback Loss Loss of motor feedback
Feedback Reversal Tachometer or Encoder wired backwards
Field Loss No field current
Field On Field current during auto-tune
Field Overcurrent Field current greater than field demand
Current Loop Loss Loss of 4-20 mA reference
External Power Supply Short circuit on +24 VDC user power supply
Power Supply Internal power supply out of tolerance
Serial Communications Mode 3 serial comms data loss Loss
Processor 1 Main control processor fault Watchdog lap
Processor 2 Watchdog Trip Second control processor fault (MD29)
Hardware Fault Hardware malfunction on control board
Memory Fault Stored parameter checksum fault
External Trip User interlock fault (programmed)
Software Fault (A29) MD29 software fault
Wide range of network communication options
User configurable analogue and digital drive inputs
Easy to use PC configuration, Software: Mentor soft
Regeneration up to 1.15 x VRMS
Available in single and four quadrant
Armature voltage, tacho or encoder feedback with loss detection
Phase sequence tolerant with loss detection
0.025% resolution for analogue speed demand
0.1% speed holding for 100% load change with tacho feedback
On-board field control with loss detection
150% overload capacity for 30 seconds with motor overload protection
Taper current limit